Got an APC Smart-UPS or a Tripp Lite SmartPro in the closet? Here's the Orion model that replaces it.
Orion Power Systems is a Jacksonville, Florida UPS manufacturer whose lineup runs from 550VA desktop units to 60kVA three-phase systems. This page is the Orion UPS vs APC and Tripp Lite cross-reference: find the model in your closet, then find the Orion that replaces it.
We sell Orion out of Jacksonville Beach, across town from where Orion designs and tests its UPS systems. You won't find prices here. Send me your model numbers and I'll send back a quote.
In most network closets, the Orion Network Pro RTX2 replaces an APC Smart-UPS SMT or SMX and a Tripp Lite SmartPro. The Orion Online RTX1 replaces an APC Smart-UPS RT/SRT or a Tripp Lite SmartOnline SU. Match on watts, not VA.
Below is Orion's cross-reference chart, plus one line I added.
Line-interactive, sine wave (network closets)
Line-interactive with external battery packs
Double conversion (online)
Desktop (front office, door access, a single PC)
Two notes on that chart. Orion calls its cross-references approximate, so check your actual load before you swap.
And the APC SURTA models on it are gone. APC discontinued the SURTA1500RMXL2U in July 2021 and points buyers to the SRT1500RMXLA instead, so if you're replacing a SURTA today, you're comparing the Orion DC1500RTX1 against an APC SRT. I break that down in our Orion Online RTX1 vs RT1L vs RTXE post.
Why watts and not VA? An APC SMT1500RM2UC is rated 1440VA but only 1000W. The Orion NP1500RTX2 is 1500VA/1350W.
Your switches draw watts, and that extra 350W is what lets you add a switch to the closet next year without buying a bigger UPS.

Most IDF closets running switches, PoE phones and access points are fine on a line-interactive UPS with pure sine wave output, which is the Orion Network Pro RTX2. Step up to double conversion (Orion's Online RTX1, RT1L or RTXE) when building power is dirty, the closet runs on a generator, or the load is lab or other sensitive equipment.
That's Orion's own guidance, too. Its UPS sizing guide says line-interactive units are "not a good fit for power quality sensitive applications such as lab equipment." A double-conversion UPS rebuilds the sine wave full-time and typically holds output voltage within ±3%.
My rule of thumb: Network Pro RTX2 in the IDFs, Online RTX1 or RT1L in the MDF where the core switch and servers live.
Add up the watts your equipment actually draws, decide how many minutes you need to ride through an outage or shut down cleanly, confirm whether the gear is 120V or 208V, then pick the Orion model whose runtime chart covers that load. Those are the 4 questions Orion asks on every quote, and they're the same 4 I'll ask you.
Here's what that looks like for a closet drawing 500W, straight from Orion's runtime charts:
Notice the pattern? One battery pack buys far more time than stepping up a model size.
Buy watts with the UPS. Buy minutes with battery packs.
Don't know your load? Once a Network Pro RTX2 is installed, its LCD shows the load level. For a new closet, I can size it from the switch model numbers.
Orion's 37-month Gold Plus warranty on the Network Pro RTX2, Online RTX1 and Online SCR3 covers the electronics and the battery for the full 37 months, with advance replacement and shipping paid both ways. APC Smart-UPS covers the UPS for 3 years but the battery for only 2. Tripp Lite SmartPro is 2 years, or 3 with registration.
Orion's terms have 2 catches. First, you have to register the UPS within 60 days of purchase. Miss it and coverage drops to 2 years on electronics and battery, so I'd register every unit the day it arrives.
Second, advance replacement means Orion ships the replacement within 1 business day of your claim, but only if you give Orion a credit card or PO for the replacement's value while the bad unit is on its way back. Return it within 14 days and nothing is charged.
With no card or PO, Orion ships after it receives the failed unit. Better to know that before a closet goes down at 7 a.m.
On connected-equipment coverage, Orion and APC both carry a $150,000 lifetime policy. Tripp Lite carries $250,000. If that's the number your risk office cares about, Tripp Lite wins it.
On the FCC's draft FY2027 Eligible Services List, UPS and battery backup appear under Category Two, as we cover in our E-Rate eligible equipment guide. The final list may differ, so confirm before you file your Form 470. Florida private and charter schools should also read who qualifies and when to start.
If your contract requires TAA, Orion sells TAA-compliant versions of its UPS lines. TAA isn't the default SKU, so you have to request it when you order.
Orion's Network Pro RTX2 and Online models cover most school closets. The rest of the catalog fills specific gaps:
You can browse the category on our power protection store page, or see who else we supply on our industries page.
Buy Orion if you're replacing APC or Tripp Lite units closet by closet and you're tired of buying batteries in year 3. With battery coverage for the full 37 months, a battery that fails inside that window is Orion's problem, not your budget's.
I'd also look hard at Orion if your district runs a mix of brands. Orion's cloud monitoring service, ViewPoint IQ, watches APC and Tripp Lite units alongside Orion, so you can see the whole fleet without ripping anything out first.
Skip Orion if you've standardized on APC network management cards across hundreds of units and your shutdown scripts are built around them. Switching mid-refresh means running 2 platforms for years. And if connected-equipment insurance is what your risk office cares about most, Tripp Lite's $250,000 policy is the bigger number.
The rest of this Orion series:
Is Orion Power Systems made in the USA?
Partly. Orion designs and tests its UPS systems in Jacksonville, Florida, and says most of its products are now either made in the USA or come from TAA-compliant countries. Its 208V NEMA PDUs are made in the USA. If your contract requires TAA compliance, specify it when you order.
Does the Orion UPS warranty cover the battery?
Yes. The 37-month Gold Plus warranty on the Network Pro RTX2 and Online RTX1 covers electronics and battery for the full term, with advance replacement and shipping paid both ways. The lithium Online RT1L and RTXE carry 60 months. Register within 60 days, or coverage drops to 2 years.
Which Orion model replaces an APC Smart-UPS SMT1500?
The Orion NP1500RTX2. Both are 2U line-interactive, sine-wave units, but the NP1500RTX2 is rated 1500VA/1350W against the APC SMT1500RM2UC's 1440VA/1000W, has 8 outlets instead of 6, and accepts up to 4 external battery packs. The SMT1500 has no external battery option.
Will an Orion UPS fit our existing racks?
Short answer: yes. The Network Pro RTX2 and Online RTX1 are 2U units that mount in a 4-post 19-inch rack with the OPS-Railkit, or in a 2-post relay rack with the OPS-2PRK depth adapter. Both also stand as towers on a closet floor, and the LCD rotates to match.
Can we monitor Orion UPS units on our network?
Every Orion UPS ships with free monitoring and shutdown software for Windows and Linux. Add the OPS-SNMP4-WEBCARD for browser and SNMP access, and Orion publishes MIB files for SolarWinds and PRTG. Orion's ViewPoint IQ subscription adds cloud monitoring across multiple buildings and brands.
Is a UPS E-Rate eligible?
UPS and battery backup are listed under Category Two on the FCC's draft FY2027 Eligible Services List. The final list may differ, so confirm eligibility before you file your Form 470. If your funding or contract also requires TAA compliance, Orion offers TAA versions, but you have to specify them when you order.
Send me the model numbers off the UPS units in your closets (a photo of the label works) and I'll send back the Orion cross-reference and a quote. Contact us today at 904.280.2544 or at sales@9to5computer.com for a quote today!
Contact us to get the best pricing in the industry.
[SCHEMA EMBEDS GO HERE — add Embed 1 and Embed 2 below as two separate HTML embed blocks, then delete this line]